| NMT NMT slave NMT master |
| Error control Heartbeat producer Heartbeat consumer: 32 message(s) |
| Boot-up Yes |
| Node ID range From 1 to 127 |
| Node ID Hardware switch Software switch Proprietary |
| CANopen bit-rates 50 kbit/s 125 kbit/s 250 kbit/s 500 kbit/s |
| Type of bit-rate adjustment Software switch |
| RPDOs 64 |
| TPDOs 64 |
| PDO modes Event-triggered Triggered by event-timer |
| PDO linking Yes |
| PDO mapping Static |
| SDO server 2 |
| SDO client 32 |
| Emergency producer No |
| Emergency consumer No |
| Sync producer No |
| Sync counter No |
| Time stamp No |
| Additional functions Self-starting device |
| CANopen version CiA 301 V 4.0.2 |
| Frameworks CiA 302 |
| Device profiles CiA 401: CANopen device profile for generic I/O modules |
| Certified No |
| Availability In stock |
Exertus Oy
Kampusranta 9
FI-60320 Seinäjoki
Phone: +358-10-4205-330
URL: http://www.exertus.fi
CDC1700S is compact sized combined display and I/O module.
The compact display controller can be used in different kinds of control and diagnostic situations. CDC1700S can also be connected to larger control systems via a CAN interface.
The CDC1700S features
Technical data
I/O-pins
CANopen compatibility makes CDC1700S easy to be added in any present or future designs.